Age | Commit message (Collapse) | Author |
|
|
|
|
|
Add alloc_size attribute and apply consistently the malloc attribute
to xmalloc, xcalloc, xrealloc, and xstrdup.
|
|
|
|
|
|
|
|
|
|
|
|
Whenever getaddrinfo needed network interface information it used the
netlink interface to read the information every single time. The
problem is that this information can change at any time.
The patch implements monitoring of the network interfaces through
nscd. If no change is detected the previously read information can
be reused (which is the norm). This timestamp information is also
made available to other processes using the shared memory segment
between nscd and those processes.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
nscd can clear caches when certain files change. The list of files
was hardcoded so far and worked for nss_files and nss_dns and those
modules which need no monitoring. nss_db, for instance, has its
own set of files to monitor. Now the NSS modules themselves can
request that certain files are monitored.
|
|
|
|
Cleanup and optimize last patch. Add timeout fixes also to the
services cache.
|
|
|
|
When readding entries to the group and services cache and the lookup
is unsuccesful, we tried to write the notfound record. Just don't
do it in this case.
|
|
This fixes BZ #12350 also for nscd.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The nscd/*cache.c files contain assert()s, writeall() and sendfileall() calls
that invalidly use together &dataset->resp and total where either dataset or
dataset->head.recsize should be used instead one of the components. In the
writeall() and sendfileall() cases, it is unlikely to matter in practice, but
the assertions can fail sometimes without a proper reason.
|
|
|
|
This reverts commit 137028b4d7e50f71906c1656c27079eac5a1d085.
Conflicts:
ChangeLog
|
|
The commit 20e498bd removes the pthread_mutex_rdlock() calls, but not the
corresponding pthread_mutex_unlock() calls. Also, the database lock is never
unlocked in one branch of the mempool_alloc() if.
I think unreproducible random assert(dh->usable) crashes in prune_cache() were
caused by this. But an easy way to make nscd threads hang with the broken
locking was.
|
|
nscd uses lockfree lists and we need to ensure the correct release
semantics is used when adding to the list.
|
|
|
|
There are two issues with the forced loop exit in the nscd lookup:
1. the estimate of the entry size isn't pessimistic enough for all
databases, resulting potentially is too early exits
2. the combination of 64-bit process and 32-bit nscd would lead to
rejecting valid records in the database.
|
|
The move to nscd-client.h was only needed for some interim version
of the patch. The final version doesn't need it. Undo the change.
|
|
The patch to bound the search in the nscd caches used a wrong exit
condition. Fixed now.
|
|
We can compute an absolute maximum for the number of elements which
can fit into the currently mapped database. Stop after that many
iterations.
|
|
The nscd database mapped in processes can change at any time. We
have to be more vigilant when it comes to using that memory. Test
the data entries are valid in their entire size, don't read data
again from memory once we verified it, and make sure the trailing
pointer is not going off the deep end.
|
|
Because we are not shutting down the other threads first another
thread might work on a query before the process shuts down. In this
case the now uninitialized libselinux and libaudit might be used.
Just don't free the resources. It's not necessary anyway because
the process is about to terminate.
|
|
warning.
* elf/sprof.c: Likewise.
|
|
from definition.
* sysdeps/x86_64/dl-machine.h (elf_machine_rela): Don't define
label if it is not used.
* elf/dl-profile.c (_dl_start_profile): Define real-type variant
of gmon_hist_hdr and gmon_hdr structures and use them.
* elf/dl-load.c (open_verify): Add temporary variable to avoid
warning.
* nscd/nscd_helper.c (get_mapping): Avoid casts to avoid warnings.
* sunrpc/clnt_raw.c (clntraw_private_s): Use union in definition
to avoid cast.
* inet/rexec.c (rexec_af): Make sa2 a union to avoid warnings.
* inet/rcmd.c (rcmd_af): Make from a union of the various needed types
to avoid warnings.
(iruserok_af): Use ss_family instead of casts.
* gmon/gmon.c (write_hist): Define real-type variant of
gmon_hist_hdr structure and use it.
(write_gmon): Likewise for gmon_hdr.
* sysdeps/unix/sysv/linux/readv.c: Avoid declaration of replacement
function if we are not going to define it.
* sysdeps/unix/sysv/linux/writev.c: Likewise.
* inet/inet6_option.c (optin_alloc): Add temporary variable to
avoid warning.
* libio/strfile.h (struct _IO_streambuf): Use correct type and
name of VTable element.
* libio/iovsprintf.c: Avoid casts to avoid warnings.
* libio/iovsscanf.c: Likewise.
* libio/vasprintf.c: Likewise.
* libio/vsnprintf.c: Likewise.
* stdio-common/isoc99_vsscanf.c: Likewise.
* stdlib/strfmon_l.c: Likewise.
* debug/vasprintf_chk.c: Likewise.
* debug/vsnprintf_chk.c: Likewise.
* debug/vsprintf_chk.c: Likewise.
|